COOLING SYSTEM

Install cooling system in the Data Center

Installation Servive , design, calculation of air conditioning systems for Data Center or Server room

      We are happy to provide comprehensive engineering services. Both design and install cooling systems in offices or industrial buildings. including in the server room and Data Center

Design and Install Cold Aisle Containment in Server Room

    Increase the efficiency of your data center air conditioning system by installing a Cold Aisle Containment system

Important factor in the server room is that the temperature inside the room must be cool.   

       Because these servers are normally open all the time. To work 24 hours a day, causing the Server to work hard and cause a lot of heat from the system. Therefore, if the temperature control system Not powerful enough to dissipate heat from the system. and enough cold air into the system If the cooling system in the room is not suitable, it will cause heat to accumulate on the server, which will result in a shorter lifespan than it should be. and can cause server system crash

     Many businesses are growing and expanding. which when it starts to grow, it is necessary to expand branches And there must always be information from both customers and various departments into the center. Therefore, it has to start to build a server room as its own central data center for the convenience of working in various forms. But creating a server room, there are many things to consider. One thing that is very important and cannot be overlooked. It is a matter of temperature, the server room must have good ventilation to prevent heat build-up. At the same time it is necessary to be careful about the humidity in the room.

   Before you design and determine the appropriateness of the temperature of the server room, you must first understand what the server room does and what must be installed. Server room is an organization’s data center. must have a computer Server has a telecommunication system. There is a device used to link the signal and Network, for example Switch and Hub  These devices need to be turned on 24 hours a day, meaning that the devices will have to heat up. And in the room it is necessary to have a ventilation system. and must have an air conditioner installed for good heat dissipation But at the same time, having an air conditioner and a cooling system for the room must be careful not to let the temperature be too cold because if the room is too cold, humidity may occur. It produces a cool mist like water vapor. which may be attached to the wall and drop down into the server equipment Therefore, the temperature standard for the server room is set to be universal. suitable temperature Should be around 20-22 degrees and that this temperature level is used universally everywhere.

  • Air conditioning  According to the temperature control standards, the server room, the air conditioning installation should be a system that is separate from the other air conditioning systems. to be a specific air conditioning system of the server room especially And there should be 2 air conditioners to work alternately In the event that one of them is broken, there will be a backup that works interchangeably. This makes it possible to control the temperature at all times.
  • Thermometer Installed to measure temperature and humidity in the room The thermometer that is installed, if it is an automatic system, has an alarm, it would be great. Or without an alarm system, the daily temperature level must be kept in mind? Another thing that cannot be forgotten is Checking the quality and operation of thermometers If it’s a battery-powered model, you’ll need to keep an eye out for it. so that constant temperature control is possible.

The matter of the server room temperature is another thing that requires great attention to detail Because if something goes wrong, it can damage the entire data center ever. In this regard, there are international standards that determine how much temperature should be set. And what should be installed? You can consult with TOTAL MAKER for free!! for budget calculation and server room design for maximum security

Air condition installation details

  1. Normally, the server room must have a temperature control in the room at 20-22 degrees.
  2. Air conditioning should be released from the bottom to the rack to drive heat upwards.
  3. air conditioner should be separated from other air conditioning systems to control the temperature of the room
  4. Must adjust the angle or turn the Rack to meet the air vent that the cold is delivered to, do not place the Rack under the air conditioner (prevent water dripping into the Rack)
  5. If a complete air conditioning system is not installed Should install 2 air conditioners, set the timer to turn on-off, switch to work in the event that one of the air conditioners is broken There is also another air conditioner that can work instead.
  6. room temperature control to install a thermometer The humidity meter shows the min-max temperature value. It should be calibrated before use. Keep a journal of your daily temperature for reference.
  7. Should have a plan to clean the air conditioner once a month or 3 months or use our MA service.

Cooling system for Data Center or Precision Air

  • It has been specifically designed for data center work and can provide cooling from under the floor. or from the ceiling down to the Server Rack
  • There is a cooling and humidity control system to create an optimal environment within the Data Center for all the IT devices installed within it.
  • The cooling system can work continuously. durable to use
  • Can work with other cooling systems (Which is a communication device) can work together to increase the cooling when the internal temperature is higher than the set.
  • humidity control system will adjust the humidity to balance through the Sensor to check the humidity Increase humidity or reduce humidity.
  • There are various models capable of cooling from 80,000 BTU to 200,000 BTU depending on the size of the Data Center.

Cooling system is an important part of Server room and Data Center. If there is no cooling system to get rid of the heat generated by computer equipment. Devices will not be able to work normally. For the server room and the Data Center, there are many types of cooling systems.

 

Air Sequnce Control Unit (ASCU)

It is a controller for the operation of 2 air conditioners by controlling the working time, temperature, etc.

The working principle of the machine is as follows.

  1. can set the working time and set the overlap period
  2. work orders immediately In case of Hightemp
  3. Alerts the working status of the ASCU such as (Over load).
  4. receive signal from outside to shut down the control system of the air conditioner

     The central job of the ASCU is to alternate ctivation of air condition in an orderly. This prevents the air condition from overloading one time.

     The ASCU will activate one set of air condition, and then alternate to the next set, For cool down before activating them again. All of this prolongs the life of the air conditioning unit, ensuring that no single part of the system is worked for too long without a break.

Air conditioning system components